Natural Gas Generator Model List Our energy working for you.TM
| 48-2200kWe Cummins Gas Generation(50HZ) |
| Designed for coninuous duty lean-burn gas heavy-loading type genset |
| 0.8PF,50HZ,3P4W,brushless, self-excitation,IP23,H level,Fuel:PNG,LNG,CNG,associated gas,coal mine gas,shale gas and so on. Gas vavle base on 33.44MJ/Nm³ |
| Model |
Continuous
power
(KWe)
|
Engine |
Alternator |
Cousumption
@full load
(KW/h)
|
Electric
effciency
(%)
|
Displacement
\cylinder
|
Measurement
\open type
(mm)
|
Heavy for
reference
(kg)
|
| C48N |
48 |
G8.3 |
UCI224E |
160 |
30.00 |
8.3(L6) |
2400*1150*1500 |
1500 |
| C55N |
55 |
GTA5.9 |
UCI224E |
167 |
33.00 |
5.9(L6) |
2200*1000*1400 |
1200 |
| C90N |
90(Prime) |
GTA8.3 |
UCDI274E |
292 |
33.00 |
8.3(L6) |
2400*1150*1500 |
1650 |
| C90N |
90 |
G855 |
UCDI274E |
290 |
31.00 |
14(L6) |
2900*1160*1900 |
3000 |
| C143N |
143 |
GTA855e |
UCI274G |
435 |
32.80 |
14(L6) |
2900*1160*1900 |
3000 |
| C165N |
165 |
GTA855 |
HCI444C |
494 |
33.40 |
14(L6) |
2900*1160*1900 |
3000 |
| C230N |
230(Prime) |
KTA19 |
HCI444E |
707 |
32.50 |
19(L6) |
3500*1300*1800 |
4000 |
| C315N5C |
315 |
QSK19 |
HCI544C |
873 |
36.10 |
19(L6) |
3500*1300*1800 |
4000 |
| C380N |
380(Prime) |
GTA28 |
HCI544D |
1124 |
33.80 |
28(V12) |
4260*2413*2489 |
6913 |
| LG329GZ* |
329 |
G9508 |
Stamford,UK |
785 |
41.90 |
16.67(V8) |
4200*1800*2500 |
5500 |
| C477N |
477 |
GTA38 |
HCI544F |
1445 |
33.00 |
38(V12) |
3900*2100*2250 |
9000 |
| LG497GZ* |
497 |
G9512 |
Stamford,UK |
1178 |
42.20 |
25(V12) |
4200*1800*2500 |
5500 |
| 575GQHA** |
575 |
QSK38 |
Stamford,UK |
1599 |
36.00 |
38(V12) |
3900*2100*2250 |
9000 |
| C610N |
610 |
GTA50 |
HCI634H |
1837 |
33.20 |
50(V16) |
5189*2400*3030 |
9885 |
| C995N5C* |
995 |
QSK60G |
Stamford,UK |
2425 |
41.00 |
60(V16) |
5120*2320*2770 |
14440 |
| C1160N5C* |
1160 |
QSK60G |
Stamford,UK |
2955 |
39.50 |
60(16) |
5000*2330*2970 |
13924 |
| C1200N5C* |
1200 |
QSK60G |
Stamford,UK |
2857 |
42.00 |
60(16) |
5120*2320*2770 |
15450 |
| C1400N5C* |
1400 |
QSK60G |
Stamford,UK |
3348 |
42.80 |
60(16) |
5120*2320*2770 |
15625 |
| C1540N5CC* |
1540 |
QSK60G |
Stamford,UK |
3546 |
43.40 |
60(16) |
5120*2320*2770 |
16000 |
| C1540N5C* |
1540 |
QSV91G |
Stamford,UK |
4021 |
38.30 |
91.6(18) |
6065*2158*2772 |
20457 |
| C1750N5C* |
1750 |
QSV91G |
Stamford,UK |
4485 |
39.00 |
91.6(18) |
5921*1720*3136 |
19633 |
| C2000N5C* |
2000 |
QSV91G |
Stamford,UK |
4888 |
40.90 |
91.6(18) |
6065*2158*2772 |
20457 |
| C2200N5C* |
2200 |
QSV91G |
Stamford,UK |
5117 |
43.00 |
91.6(18) |
6065*2158*2790 |
20477 |
| 46-2000kWe Cummins Gas Generation(60HZ) |
| Designed for coninuous duty lean-burn gas heavy-loading type genset |
| 0.8PF,60HZ,3P4W,brushless, self-excitation,IP23,H level,Fuel:PNG,LNG,CNG,associated gas,coal mine gas,shale gas and so on. Gas vavle base on 33.44MJ/Nm³ |
| Model |
Continuous
power
(KWe)
|
Engine |
Alternator |
Cousumption
@full load
(KW/h)
|
Electric
effciency
(%)
|
Displacement
\cylinder
|
Measurement
\open type
(mm)
|
Heavy for
reference
(kg)
|
| C46N6 |
46 |
G5.9 |
Stamford,CN |
153 |
30.00 |
5.9(L6) |
2200*1000*1400 |
1200 |
| C60N6 |
60 |
G5.83 |
Stamford,CN |
194 |
31.00 |
8.3(L6) |
2400*1150*1500 |
1650 |
| C78N6 |
78 |
GTA5.9 |
Stamford,CN |
233 |
33.50 |
5.9(L6) |
2200*1000*1400 |
1200 |
| C108N6 |
108 |
G855 |
Stamford,CN |
328 |
32.00 |
14(L6) |
2900*1160*1900 |
2900 |
| C128N6 |
128 |
GTA8.3 |
Stamford,CN |
379 |
33.80 |
8.3(L6) |
2400*1150*1500 |
1650 |
| C172N6 |
172 |
GTA855e |
Stamford,CN |
513 |
33.50 |
14(L6) |
2900*1160*1900 |
2900 |
| C192N6 |
192 |
GTA855 |
Stamford,CN |
568 |
33.80 |
14(L6) |
2900*1160*1900 |
2900 |
| C257N6 |
257(Standby) |
GTA855 |
Stamford,CN |
779 |
33.00 |
14(L6) |
2900*1160*1900 |
2900 |
| C355N6 |
355(Standby) |
KTA19 |
Stamford,CN |
1075 |
33.00 |
19(L6) |
3500*1300*1800 |
4000 |
| C334N6C* |
334 |
QSK19G |
Stamford,UK |
879 |
36.10 |
19(L6) |
3500*1300*1800 |
4000 |
| C470N6 |
380 |
GTA28 |
Stamford,CN |
1124 |
33.80 |
28(V12) |
4267*2413*2489 |
6913 |
| C495N6 |
495(Standby) |
GTA28 |
Stamford,CN |
1478 |
33.50 |
28(V12) |
4267*2413*2489 |
6913 |
| C451N6 |
451 |
QTA38 |
Stamford,CN |
1367 |
33.00 |
38(V12) |
3900*2100*2250 |
9000 |
| C543N6 |
543 |
GTA38 |
Stamford,CN |
1621 |
33.50 |
38(V12) |
3900*2100*2250 |
9000 |
| C692N6 |
692 |
GTA50 |
Stamford,CN |
2047 |
33.80 |
50(V16) |
5189*2400*3030 |
9885 |
| C700N6 |
700(Standby) |
GTA38 |
Stamford,CN |
2083 |
33.60 |
38(V12) |
3900*2100*2250 |
9000 |
| C740N6 |
740(Prime) |
GTA50 |
Stamford,CN |
2176 |
34.00 |
50(V16) |
5189*2400*3030 |
9885 |
| C895N6 |
895(Standby) |
GTA50 |
Stamford,CN |
2632 |
34.00 |
50(V16) |
5189*2400*3030 |
9885 |
| C1000N6C* |
1000 |
QSK60G |
Stamford,UK |
2325 |
43.00 |
60(16) |
5120*2320*2770 |
15625 |
| C1100N6C* |
1100 |
QSK60G |
Stamford,UK |
2533 |
43.40 |
60(16) |
5120*2320*2770 |
15625 |
| C1250N6C* |
1250 |
QSK91G |
Stamford,UK |
3294 |
37.90 |
91.6(18) |
6240*2100*2970 |
19337 |
| C1400N6C* |
1400 |
QSV60G |
Stamford,UK |
3795 |
36.90 |
60(16) |
5000*2330*2970 |
13924 |
| C1540N6C* |
1540 |
QSV91G |
Stamford,UK |
4374 |
35.20 |
91.6(18) |
7360*2110*2970 |
21089 |
| C1750N6C* |
1750 |
QSV91G |
Stamford,UK |
4572 |
38.30 |
91.6(18) |
7360*2110*2970 |
21089 |
| C2000N6C* |
2000 |
QSV91G |
Stamford,UK |
5004 |
40.00 |
91.6(18) |
7120*2160*2780 |
20705 |
|
1.Voltage Option:440/260V,440/254V,415/240V,900kW and above can choose high voltage generator.
2.Alternator Stamford.
3.Prime Power:In unstable load genset could be running continuous,It allows one hour of 10% overload in 12 hours.(Stamford:ISO8528)
4.Continous Power:in the variable power of genset continuous runnin.
5.* means CUMMINS UK,** means CUMMINS India. Other models means assembled by Cummins OEM Partners.
6.Emission standard:*and** means NOx less than 500mg, other models comply USA EPA Standard.
|
Far East Power Investment (Chengdu) Co., Limited
Basic Information
Business Type:
Main Products: CHP,CCHP,Gas Generator,Natural Gas Generator,Biogas Generator
Location:
Total Employees:
Year Established:
Trade Information
Top 3 Markets:
Accepted Payment Currency:
Nearest Port:
Average Lead Time:
Overseas Office: No
Company Pictures
Verified Supplier
Credit Check