Remove Now
Cancle
Coverter HART to modbus rtu

Coverter HART to modbus rtu

FOB Reference Price / Min.Order Quantity : Get Latest Prices

Processing Time:1 Days - 60 Days

Packaging Details: STANDARD EXPORTING PACKAGE

Port: Shanghai / Shenzhen / Qingdao / Ningbo / Other

Payment Terms: L/C , T/T , other

img img img

Packaging & Delivery

Packaging Details: cartons
Delivery Detail: within 1 day to 1 month according to the order amount

Specifications

 

modbus rtu
DIN Rail Mounting
supports TTL level, RS485 and RS232
Communication Protocol Converter

 

 

 Coverter HART to modbus rtu

 

1. System Overview

 

NCS-MH105 converter is a newly R&D converter between MODBUS-RTU protocol and HART protocol. As MODBUS host, NCS-MH105 converter communicates with the device with MODBUS-RTU communication function via RS485 interface, and it is able to convert the data in the device to HART device variable output, supporting 4~20mA current output.

 

As a HART device, NCS-MH105 converter can get through HART system with HART modem and PC. It is able to configure parameters of NCS-MH105 converter via HART configuration software, shown as Figure 2.

 

2 Device Performance Index

NCS-MH105 converter has powerful processing capacity, and the hardware parameters are shown as following:

Parameter

Detail

Bus signal

4~20mA output with HART protocol,

Bus power supply

11.9~45V

Operating temperature

-40 ~85°C

Humidity range

5% ~ 95%,non-dew

Mechanism size

96mm × 56mm(can be customized)

CPU

M430F149

FLASH

60K

RAM

2K

EEPROM

2K

NCS-MH105 converter and MODBUS device communicate with each other via standard MODBUS-RTU protocol. NCS-MH105 converter is used as master station, and MODBUS device is used as slave station. The default parameters are shown as following:

Parameter

Default value

Address

1

Baud rate

9600

Data bit

8

Stop bit

1

CRCcalibration

low byte ahead

The function codes supported by NCS-MH105 converter shown as following:

Function code

Function

1

read loop status

2

read discrete input status

3

read keeping register value

4

read input register value

6

write loop

16

write multiple register values

Microcyber Corporation

Business Type:

Main Products:

Location:Floor 1-3, Building 1, No. 17-8, Wensu Street, Hunnan New Area, Shenyang, Liaoning, China (Mainland) Zip: 110179

Total Employees: 101 - 200 People

Year Established: 2003

Top 3 Markets:

Accepted Payment Currency:

Nearest Port:

Average Lead Time:

Overseas Office: No

Coverter HART to modbus rtu