Touch Screen Fetal/Maternal Monitor CTG Belt

Touch Screen Fetal/Maternal Monitor CTG Belt

FOB Reference Price / Min.Order Quantity : Get Latest Prices

Processing Time:1 Days - 60 Days

Packaging Details: STANDARD EXPORTING PACKAGE

Port: Shanghai / Shenzhen / Qingdao / Ningbo / Other

Payment Terms: L/C , T/T , other

img img

MD2000C Computer Automatic Rea-time Online Analytical Maternal-Neonatal Monitor 

Computer Automatic Real-time On-line Analytical Function 

This function have get our National Invention Patents . 

 

 

2000C Computer Automatic Real-time On-line Analytical Maternal-Neonatal Monitor , have two monitoring interface . 

 Pregnant women & Fetal Monitoring together , Fetal Monitoring two kinds . 

 The pregnant women & fetal monitoring , except the FHR , FM & TOCO monitoring , also will monitoring the pregnants'RESP , HR , SPO2 , HIBP , PR , TMP . 

 The fetal monitoring interface , monitoring the FHR , FM & TOCO especially , not only can shows the FHR , FM & TOCO Curves , but also give the Real-time On-line Analytical Results , the monitoring will given in the same screen . 

 

 From the above photos , we can see that our products is truly realize the automatic diagnosis of fetal monitoring , make each of obstetrics and gynecology doctors can analysis and diagnosis of fetal monitoring graphics easily and accurately.

 On the fetal monitoring graphics, it can shows the fetal heart rate baseline,accelerated change, deceleration change, the situation of variation , the change of uterine contraction , fetal movement , various parameters changes , then shows on the screen .After the monitoring , the conclusion and score is given automatically . 

 

 So our Computer Automatic Real-time On-line Analytical Function has the advantages of Real-time , Process , Parameters and Comprehensive . 

 

 

 

1.0 MHz Digital Pulse Ultrasonic Broadband Technology >>>

This technology have get our National Invention Patents . 

 

For our products , it has the function of Computer Automatic Real-time On-line Analytical , we adopt the 1.0MHz Digital Pulse Ultrasonic Broadband Technology , have get our National Paten . The message below is the advantages of our this technology .

 

1.Wide Sound Beam . Made the machine has a wide range of fetal heart caputre. Fetal heart capture is not affected by the fetal movement and uterine contraction effect . 

 

2.Adopt the DSP technology , make the machine strng anti-jamming capability ,almost zero moise . 

 

3.Adopt the 1.0MHz Digital Pulse Ultrasonic Broadband Technology , the attenuation is small , strong echo , high sensitivity , easy to capture the fetal heart . 

 

4.Stable performance , Realiable quality . 

 

 


 
 

 

MD2000C Computer Automatic Rea-time Online Analytical Maternal-Neonatal Monitor 

 

            FHR Ultrasonic Frequency and the way: 1.0MHz,12 chips,digital pulse ultrasonic broadband
Measurement Range : 40-220BPM
Accuracy : Within ±1BPM
Fetal Heart Voice : 1-8 degree , Adjustable 
           TOCO Record Range : 1-100 relative unit
Non-line Error : ‹±10%
          Fetal Movement Automatic Fetal Movement Mark
                      Sp02 Measurement Range : 50% - 100%
Accuracy : Within70% - 100% , ‹±4%
                      PR Measurement Range: 30-240t/min
Accuracy : Within ±10%
                        Temp Temp Unite : °c
Temp Measurement Range : 26-45°c
Temp Measurement Accuracy : Within ±0.2°c

               ECG

Lead Mode : 3-lead,  I/II/III  :  5-lead:  I/II/III /AVR/AVL/V
HR Measurement Range : 15-300bpm
HR Alarm Limit and Accuracy:Upper Limit:60-300BPM,Accuracy:±10%                                                                                         Inferior Limit:10-200BPM,Accuracy:±10%
Alarm Time : Since the heart rate, out-of-limit occurs to the time of the alarm is less than 12s
HR Measurement Accuracy : 1BPM or ±1% , Either the maximum value of .
Frequency Response: Filer Way:1-25Hz              Non-filer:0.5-100Hz
Waveform Scanning Speed : 6.25mm/s , 12.5mm/s , 25mm/s , 50mm/s 
Waveform Scanning Speed Accuracy: ≤±10%
Defibrillation Recovery Time: ‹5s (Monitor or Operation Mode)
ECG Measurement Range : When the standard sensitivity , the heart rate measurement signal range is ±0.5mV ~ ±3mV
The Standard Signal Accuracy : 1mV±5%
                        NIBP Oscillometry
Mode:Mannual / Automatic
Unite: mmHg , kpa

Measurement Range: SBP:40mmHg - 250mmHg(5.3kpa-33.25kpa)

                                   DBP:20mmHg - 220mmHg(2.66kpa - 29.26kpa)

                                   MAP:30mmHg - 240mmHg(3.99kpa - 31.92mmHg)

Measurement Accuracy : ‹ ±10% , or ±0.5kpa(±3.75mmHg) , Either the maximum value of 

 

 

 

Taian Medi Medical Electronic Co., Ltd.

Business Type:

Main Products: fetal monitor,maternal monitor,fetus-voice meter,glucose meter,oximetry

Location:Zone A-8, Taishan Tech City, High And New Technology Industrial Development Zone, Tai'an, Shandong, China (Mainland)

Total Employees: 101 - 200 People

Year Established: 1998

Top 3 Markets:

Accepted Payment Currency:

Nearest Port:

Average Lead Time:

Overseas Office: No

Touch Screen Fetal/Maternal Monitor CTG Belt