T Type Continuous Working X Ray Flaw Detector
FOB Reference Price / Min.Order Quantity
: Get Latest Prices
Processing Time:1 Days - 60 Days
Packaging Details:
STANDARD EXPORTING PACKAGE
Port: Shanghai / Shenzhen / Qingdao / Ningbo / Other
Payment Terms: L/C , T/T , other
Features and Specifications of T Type Portable X-ray Flaw Detector with Ceramic X-Ray Tube
★ Adopt the newest energy conversion, and rose to high-frequency operation, which make energy conversion rate improved by 30% compared with the traditional equipment, break through the traditional 1:1 working mode, no rest time requirement.
★ Low heat, continuous working does not affect the service life.
★ 4000 turn all metal cooling fan make larger effective heat dissipation area; There will be no frequent over temperature protection during the full power continuous operation.
★ Non flange design, small and beautiful apperance; End ring groove design make it easy to fix on the top of the pipe.
★ Using high frequency paper film transformer, with strong heat resistance, low heat, High working efficiency and Low failure rate.
| Model |
XXG/2005T |
XXG2505T |
XXG/3005T |
XXG/3505T |
| XXGHZ/2005T |
XXGHZ/2505T |
XXGHZ/3005T |
XXGHZ/3505T |
| Power Supply |
160V - 255V 50 - 60HZ |
| Power Capacity |
>1.0KVA |
>1.5KVA |
>2.0KVA |
>2.5KVA |
| Tube Voltage |
100KV-200KV |
150KV-250KV |
170KV-300KV |
220KV-360KV |
| Tube Current |
5mA |
|
X-Ray Generator Size (mm)Ф×H
|
φ165×560 |
φ200×590 |
φ230×600 |
φ260×650 |
| φ165×560 |
φ200×590 |
φ230×600 |
φ260×650 |
| X - Ray Beam Cone Angle |
40° |
| 40°× 360° |
| Controller Size(mm) |
350×300×135 |
| Controller Weight |
10kg |
| Controller Delaying Time |
0 - 1 min. |
| Timing Range and Error |
9.9 min Minute Error ±1% |
| Working Mode |
Continuous Working; Exposure at any time; No mandatory rest |
| Insulation |
SF6 Gas |
| Cooling |
Radiator forced air cooling |
| Safety Working Pressure |
0.35 - 0.6 Mpa |
| X-Ray Generator Weight(kg) |
17 |
24 |
32 |
34 |
| 16 |
23 |
31 |
33 |
| Max. Penetration (mm) |
30 |
40 |
50 |
75 |
| 23 |
34 |
44 |
70 |
| Working Conditions of X-ray Photography |
1. Focus to Film: 600mm 2. Exposure time: 5 min. 3. Film: TianJin, Model III, intensified by double lead foil. 4. Treatment in the darkroom: Temp. 20 ±2ºC, 5 min. blackness ≥ 1.5. sensitivity≤2% |

YUSHI INSTRUMENTS
Basic Information
Business Type:Business Service
Main Products:serious ultrasonic thickness gauge, ultrasonic flaw detector, coating thickness gauge, leeb hardness tester, UV Lamp, industrial LED X-ray film viewer, black-white densitometer, X-ray flaw detector
Location:
Total Employees:
Year Established:
Trade Information
Top 3 Markets:
Accepted Payment Currency:
Nearest Port:
Average Lead Time:
Overseas Office: No
Company Pictures
Verified Supplier
Credit Check