Remove Now
Cancle
FXK-009SMII 9kw normal temperature heating & cooling heat pump
FXK-009SMII 9kw normal temperature heating & cooling heat pump

FXK-009SMII 9kw normal temperature heating & cooling heat pump

FOB Reference Price / Min.Order Quantity

USD 0.00-1.00 / Set/Sets | 2.00 Set/Sets (Min. Order)

Processing Time:7-45 days

Packaging Details: Plywood

Port: Foshan

Payment Terms: ,

img

cNormal temperature heating & cooling heat pump

MODEL

FXK-009SMII

FXK-013SMII

FXK-018SMII

FXK-024UII

FXK-034UII

FXK-042UII

FXK-084UII

Power

380V /3N /50Hz

Working ambient range

-15℃~45

Rated heating capacity (A7W35)

Heating capacity(A7W45)

kW

9.00 

13.60 

18.20 

24.30 

34.40 

42.70 

84.60 

Input power

kW

2.18 

3.42 

4.44 

5.90 

8.75 

10.84 

21.36 

COP

/

4.12 

3.98 

4.10 

4.12 

3.93 

3.94 

3.96 

Working current

A

4.15 

6.49 

8.43 

11.20 

16.62 

20.58 

40.57 

Rated cooling capaciy

Cooling capacity

kW

7.20 

11.50 

16.50 

21.00 

27.50 

35.00 

68.00 

Input power

kW

2.57 

4.09 

5.79 

7.34 

9.72 

12.41 

23.61 

COP

/

2.80 

2.81 

2.85 

2.86 

2.83 

2.82 

2.88 

Max.working current

A

8.00 

12.00 

14.00 

18.00 

26.00 

30.00 

60.00 

Max.input power

kW

5.80 

7.00 

7.80 

11.50 

14.50 

16.50 

33.00 

Max.outlet water temp.

60.00 

60.00 

60.00 

60.00 

60.00 

60.00 

60.00 

Compressor

Brand

/

Panosonic / Rotary

Copeland / scroll

Copeland / scroll

Copeland / scroll

Copeland / scroll

Copeland / scroll

Copeland / Scroll

QTY

Pics

1.00 

1.00 

1.00 

1.00 

2.00 

2.00 

4.00 

Refrigerant

/

R410a

R410a

R410a

R410a

R410a

R410a

R410a

Air discharge

/

Side discharge

Side discharge

Side discharge

Side discharge

Side discharge

Side discharge

Side discharge

Motor QTY

/

2.00 

2.00 

2.00 

2.00 

2.00 

2.00 

2.00 

Heat exchanger Max pressure

MPa

4.20 

4.20 

4.20 

4.20 

4.20 

4.20 

4.20 

Suction/exhaust Max pressure

MPa

4.20 

4.20 

4.20 

4.20 

4.20 

4.20 

4.20 

Water side Max.Pressure

MPa

1.00 

1.00 

1.00 

1.00 

1.00 

1.00 

1.00 

Waterproofing Grade

/

IPX4

IPX4

IPX4

IPX4

IPX5

IPX6

IPX7

Anti-electric shock

/

I

I

I

I

I

I

I

Water flow

m³/h

2.20 

2.20 

2.84 

3.61 

4.73 

6.02 

11.70 

Water side pressure reduce

kPa

≤40

≤40

≤40

≤50

≤50

≤60

≤70

Noise

dB(A)

≤58

≤60

≤60

≤65

≤65

≤68

≤70

Net Size (L*W*H)

mm

1030×380×1335

1030×380×1335

1030×380×1335

830×790×1070

1500×690×1070

1500×690×1270

2100×1100×2000

Weight

kg

80 

90 

130 

250 

350 

380 

880 

 

 

 

 

 

 

 

 

 

 

1. Rated heating conditions A7/W35: outdoor air temp. 7℃ DB/6℃ WB, inlet water temp. 30℃, outlet water temp. 35℃.

2. Rated cooling conditions A35W7 : outdoor air temp. 35℃ DB/24℃ WB, inlet water temp. 12℃, outlet water temp. 7℃.

Heat Pumps work by moving heat from one place to another using energy to perform this task. They are used for heating indoor buildings, but they also have outdoors applications such as warming up Swimming Pools. If you are interested in our Water and Ground Source Heat Pump Dryer, Water Source Heat Pump 17KW, you can email or call us at any time. More information please view here.

 

Foshan Airosd Thermal Technology Co.,Ltd

Business Type:Business Service

Main Products:ir source heat pump, low temperature heat pump

Location:

Total Employees: 160

Year Established: 2003

Top 3 Markets:

Accepted Payment Currency:

Nearest Port:

Average Lead Time:0

Overseas Office: No

FXK-009SMII 9kw normal temperature heating & cooling heat pump