Remove Now
Cancle
6CRE50500 spark killer for NC mchine tools RC network

6CRE50500 spark killer for NC mchine tools RC network

FOB Reference Price / Min.Order Quantity : Get Latest Prices

Processing Time:1 Days - 60 Days

Packaging Details: STANDARD EXPORTING PACKAGE

Port: Shanghai / Shenzhen / Qingdao / Ningbo / Other

Payment Terms: L/C , T/T , other

img

Specifications

 

spark killer for NC mchine tools RC network
1)Minimize the occurrence of arcing and noise
2)Overload capacity is large
3)Used
 

 

spark killer for NC mchine tools RC network RC NETWORKS

Our products can be widely used in aerospace, defense, mechanical, chemical industry, metallurgy industry by use of contactor, relays, electromagnetic valve easy generation of arc or disconnect the overvoltage main circuit and control circuit, so as to eliminate arc, over-voltage, reduce interference, prolong the life, electric components for electromechanical products is indispensable over-voltage protection device.

 

 

 

 

Features
 

  •  Broad use in industrial applications.
  •  External mounting tab.
  •  1/2 watt non-inductive, high pulse resistor.
  •  Three phase delta connection (3 CRE).  Three phase three line (6 CRE).
  • Circuit
  • 6CRE

    Electrical Specifications

    Model
    Number
    Capacitance
    μF±20%
    Resistance
    Ω±30%
    Pulse condition (max.) Peak Pulse Voltage Test
    Voltage
    Insulation
    Resistance
    Peak to peak Pulse width Repetitive frequency Pulse width (sec) x Frequency(Hz)
    CRE-10201 0.1 200(1/2W) 700V 50msec.
    70msec.
    360Hz. 0.45 800V
    max.
    Line to Line
    625VAC
    50/60Hz 60sec
    Line to Case
    2,000VAC
    50/60Hz 60sec
    Line to Line
    10,000MΩ
    min.
    Line to Case
    100,000MΩmin. (at 500VDC)
    CRE-20151 0.2 150(1/2W) 0.15
    CRE-30680 0.3 68(1/2W) 0.1
    CRE-50500 0.5 50(1/2W) 0.07
    3CRE-30680 0.3/1 phase 68 (1/2W) /1 phase 0.1
    3CRE-50500 0.5
    /1 phase
    50(1/2W)
    /1 phase
    0.07  
    6CRE-50500

     

    Recent developments in electronic equipment have shown the following trends:

     

    Increasing demands for numerical control machines,robotics and technically advanced appliances are requiring progressive electronic technologies. When employing integrated circuit and microcomputer technology, today's equipment is requiredto perform multifunction in limited size. The de nser the installation of components, the more the components must be miniaturized and of lighter weight.

     

    1) Using Spark Quenchers will help prevent abnormal operation due to electrical noise and/or surge pulses. It is not recommended that these devices be used in circuits with frequencies greater than 70 Hz. When used in 3-phase, full wave rectified applications, care must be taken to insure that the Spark Quencher does not self heat by more than 5 degrees centigrade or permanent damage to the Spark Quencher may occur.

     

    2) When protecting contacts feeding small circuit loads, it is recommended that the Spark Quencher be placed in parallel with the load, rather than the contacts, for the most effective application.

     

    3) In high speed circuits, the addition of a Spark Quencher may slow the response time of the circuit. For best response characteristics, do not use a larger Spark Quencher than is absolutely necessary to suppress the noise level.

     

    4) Spark Quenchers should be connected as close as possible to the noise source. Excessive lead length may allow abnormal oscillation and/or decrease energy absorption capacity.

     

    5) When a thyristor, triac or invertor circuit is to be protected by a Spark Quencher, care must be taken that high harmonic currents do not cause over heating of the Spark Quencher resistor. If heating occurs, we suggest the employment of a Spark Quencher with a lower resistance. The Spark Quencher must not self heat by more than 5 degrees centigrade. In invertor applications, it is recommended that an noise suppression capacitor be used across the power lines, instead of the Spark Quencher.

     

    6) While it may appear effective to protect contacts with a capacitor only, the capacitor discharge current will cause accumulative damage to the contacts when they close. The proper technique is to apply a Spark Quencher across either the contacts or the load.

    Spark Quenchers have the following characteristics which make it possible to easily use them in a wide range of applications.


    1) The Overload capacity is large.
    2) They are not polarized; thus can be used in both AC an DC circuits.
    3) They have a favorable effect on surge voltage and accompanying oscillations caused by contact chatter.
    4) They are effective against spurious potentials having magnitudes below circuit voltage.
    5) They offer a high degree of protection for semiconductor devices, and as thyristors and SCRs.
    6) They improve the dv/dt ratio.

Dalian Haokang Electronic Technology Co., Ltd.

Business Type:

Main Products:

Location:Group 2, Huoshiling Village, Shuishiying St., Lvshunkou District, Dalian, Liaoning, China (Mainland)

Total Employees:

Year Established: 2008

Top 3 Markets:

Accepted Payment Currency:

Nearest Port:

Average Lead Time:

Overseas Office: No

6CRE50500 spark killer for NC mchine tools RC network