132KV Outdoor Oil-immersed Type Voltage Transformer

132KV Outdoor Oil-immersed Type Voltage Transformer

FOB Reference Price / Min.Order Quantity : Get Latest Prices

Processing Time:1 Days - 60 Days

Packaging Details: STANDARD EXPORTING PACKAGE

Port: Shanghai / Shenzhen / Qingdao / Ningbo / Other

Payment Terms: L/C , T/T , other

img

1. General

KEMA Type Test,  Outdoor, Oil-immersed inductive type, single phase, used for metering and relay protection of 110kv or 132kv, 50HZ or 60HZ system, applying to highland area, individual measuring and protective winding, cascade structure, voltage transformer, 132KV High Voltage Transformer

2. Standards

IEC Standard:IEC60044-2<Inductive Voltage Transformer>

National Standard;

GB1207<Voltage Transformer>

GB311.1<Insulation Co-ordination for High Voltage Transmission and Distribution Equipment>

3. Service Condition

Ambient Temperature:-40~+40°c

Altitude:

JDCF-110(W1,W2,W3) less than 1000m

JDCF-110GY(W1,W2,W3) less than 3500m

Environment Pollution Level:II, III, IV

4. System Condition

System Rated Voltage:110kv

System Highest Voltage: 126kv

System Rated Frequency: 50HZ or 60HZ

System Neutral Earthing Method: Effectively Earthed

5. Structure Feature

  • It is cascade structure, which the primary winding has two grade windings surrounded on each limbs of one single phase two-limb core. The insulation consists of high voltage cable paper, phone paper and cardboard etc., which will  be immersed with transformer oil after desiccating under vacuum. It has advantages of stable and reliable performance of insulation, rich successful experience, a long life time and convenient maintenance.
  • Perfect fluidity performance of transformer oil is good for heat dissipation, it also has self recover ability for the failure of partial discharge caused by air bubble and dust
  • It has three secondary windings, which has individual measuring and protection winding
  • Hermetically sealed stainless steel metallic bellows is installed on the top, which protect the transformer oil from moisture and extend the life time, also there is a oil level gauge on the bellows for observing the changing of oil volume
  • There is a multi function oil drain valve on the base, which make it more convenient for sampling, draining and refilling
  • The secondary terminal board is made of epoxy cating, the seal performance is more reliable
  • The base use DACRAL(Zinc/Chromate coatings) for resistance to corrosion, which gives a high degree of corrosion resistance.

Dalian North Instrument Transformer Group Co., Ltd.

Business Type:

Main Products:

Location:

Total Employees:

Year Established:

Top 3 Markets:

Accepted Payment Currency:

Nearest Port:

Average Lead Time:

Overseas Office: No

132KV Outdoor Oil-immersed Type Voltage Transformer